Technical Specifications

Generator Power3.0 kW High-Frequency Resonant Inverter
Input Voltage110–230 VAC, 50/60 Hz (Universal Input, PFC)
kVp Range40–120 kVp (1 kV steps, closed-loop regulated)
mA Range12.5–60 mA — Dynamic, kV/Time Dependent
mAs Range0.125–200 mAs
Exposure Time0.01–3.33 seconds
DisplayDigital — kVp, mAs, Exposure Time
IndicatorsX-Ray, Ready, mA Station, Fault
X-Ray TubeStationary Anode, 130 kVp
Focal Spot1.2 mm
Target MaterialTungsten
Target Angle15°
Anode Capacity30,000 HU Storage
Filtration4.3 mm Al equivalent at 120 kVp
CollimatorCollimare CPL-125-SR01-C (CFR 21 Subchapter J)
Max F/S to Floor78″ / 198 cm
Head Rotation180° Horizontal / 300° Vertical
System Weight (Classic Stand)115 lbs / 52 kg
System Weight (Lightweight Stand)Under 100 lbs / 45 kg
ConfigurationsAnalog, Digital-Ready, Full Digital
CertificationsMDSAP / ISO 13485
Warranty3-Year Limited

Source-Ray PowerMax 1260

The Source-Ray PowerMax 1260 was originally designed for the military with agility in mind. Its compact, lightweight construction makes it easy for an operator to move the system effortlessly, while delivering maximum mR/mAs and 3.0 kW of power across the entire kV range. The PowerMax 1260 produces hospital-quality imaging and offers an easy upgrade path for clinical sites transitioning to digital. Universal-input with power factor correction, dynamic mA selection, and a 130 kVp stationary-anode tube — available with the Classic Stand or the New Universal Lightweight Stand in Full Digital, Digital-Ready, or Analog configurations.

Key Features & Highlights

  • 3.0 kW maximum power output across the entire kV range
  • 40–120 kVp range with closed-loop regulation in 1 kV steps
  • Dynamic mA — selectable 12.5–60 mA, dependent on kV or time
  • Universal input with Power Factor Correction
  • Originally engineered for military field deployment
  • Available on Classic Stand or New Universal Lightweight Stand
  • Optional 16″ air-filled tires, solid wheels, panel storage box
  • High-frequency resonant inverter — 30,000 HU anode capacity
  • Limited 3-year warranty

Ideal Applications

Hospital BedsideEmergency DepartmentMilitary Field UseOperating RoomICU / CCUMobile Imaging ServiceSports Medicine / Team PhysicianDisaster ResponseCorrectional Facility

Brand & Compliance

UL RecognizedFDA ClearedMDSAPISO 13485CFR 21 Subchapter J
Manufacturer: Source-Ray, Inc.
Country of Origin: United States
Founded: 1994

Request a Quote for the PowerMax 1260

Contact our specialists for pricing, availability, and configuration options tailored to your practice.

Request a Quote View All Source-Ray Products

Interested in the Source-Ray PowerMax 1260?

Our team will provide expert guidance and a competitive quote for your practice.