UC-5000
Full Mobile DR X-Ray System with Integrated Workstation
Technical Specifications
| Generator Power | 5.0 kW Nominal — High-Frequency Inverter |
|---|---|
| Max Output Power | 5 kW Instantaneous (100 kVp @ 5 mAs) |
| Long Exposure Power | 2.5 kW (100 kVp @ 125 mAs) |
| Input Voltage | 115 VAC 60 Hz / 230 VAC 50 Hz |
| kVp Range | 40–110 kVp |
| mA Range | 10–50 mA |
| mAs Range | 0.1–200 mAs |
| Exposure Time | 0.01–5.00 seconds |
| kVp Accuracy | ±5% of full scale |
| mA Accuracy | ±5% |
| mAs Accuracy | ±15% or 0.5 mAs (whichever greater) |
| Timer Accuracy | ±2% +1 ms |
| Duty Cycle | 3% (1 s ON / 30 s OFF, automatic) |
| Equipment Class | Class II — Intermittent Mode |
| Indication for Use | General Purpose Radiography (Film / CR / Digital) |
| Compatibility | Film, Computed Radiography, Direct Digital DR |
| Standards | IEC 60601-1-3, 60601-2-54, 60601-2-28 |
| Compliance | 21 CFR Subchapter J |
| Configuration | Self-Contained Mobile Cart with Workstation |
Source-Ray UC-5000
The Source-Ray UC-5000 is a complete mobile X-ray system built for general-purpose hospital radiography. Unlike traditional portables, the UC-5000 is a self-contained mobile cart with an integrated power inverter, generator assembly, and stand assembly — engineered for film, computed radiography (CR), or direct digital flat-panel use. Delivering 5.0 kW of constant-potential power from a high-frequency inverter and supporting 10–50 mA tube current at 40–110 kVp, the UC-5000 is designed for routine hospital workflows where a full mobile DR workstation is required.
Key Features & Highlights
- 5.0 kW nominal electric power — constant-potential, regulated kVp & mA
- 40–110 kVp range with closed-loop regulation
- Tube current 10–50 mA, exposure 0.01–5.00 s, mAs 0.1–200
- Class II Intermittent Mode — UL recognized, CFR 21 Subchapter J
- Integrated mobile cart with power-driven motion (typical configuration)
- Compatible with film, CR, or direct digital flat panels
- Engineered for routine hospital radiography workflows
- IEC 60601-1, 60601-2-54, and 60601-2-28 safety compliance
- Designed for general-purpose radiography (not for mammographic use)
Ideal Applications
Brand & Compliance
Country of Origin: United States
Founded: 1994
Request a Quote for the UC-5000
Contact our specialists for pricing, availability, and configuration options tailored to your practice.